- Stock: In Stock
- Brand: Power Guard
- Model: Power Guard 1200VA CS Offline UPS (Plastic Body)
Key Features
- Load Capacity 720W
- Display Type LED Display
- Input Voltage 145-280V
- Output Voltage 220/230 VAC +/-10%
- Frequency (Battery Mode) 50/60Hz +/-5%
- View More Info
| Main Features | |
| Load Capacity | 720W |
| Display Type | LED Display |
| Input Voltage | 145-280V |
| Output Voltage | 220/230 VAC +/-10% |
| Frequency (Battery Mode) | 50/60Hz +/-5% |
| Battery | Lead-Acid Miantenance-Free, 2 ps with 12V & 7.2Ah |
| Alarm | Beeping Alarm |
| Output Features | |
| Backup Time | 25-30 Minute (1PC & 1 Monitor) |
| Type of Wave | Modified-Sinewave |
| Transfer Time | 2-6 ms Typical |
| Warranty Details | |
| Warranty | 1 year Under the following conditions, the warranty would not be provided: • UPS burning due to thunder, abnormal overload, insect entrance and others. • If ambient temperature should not be maintained at 20 to 26 degrees Celsius with proper dehumidification. (24/7) • If the product is placed in a dusty and damp place. • In the absence of Generator connectivity Without proper battery charge, the warranty will be void. • Battery swelling and overcharging due to the wrong system voltage setting of the UPS. |
Power Guard 1200VA CS Offline UPS (Plastic Body)
The Power Guard 1200VA CS Offline UPS features Automatic voltage regulation(AVR), High/ Low Voltage Protection, Overload/ Short Protection Cool. This Power Guard UPS featured an input voltage range of 145-280VAC and a frequency of 50/60Hz+/-5%. It offers an output voltage of 220/230VAC+/-10%. It has a transfer time of 2~6 ms (Typical) and a Pure Sine Wave. The Power Guard 1200VA UPS is equipped with a Lead-Acid Maintenance-Free battery. It takes a recharge time of 6 hours up to 90% capacity. It can deliver a backup time of 05-20 mins (Depending on load). This UPS indicates AC Mode with Green lighting, Battery Mode with Red lighting, and Over Load Yellow lighting. The Power Guard 1200VA CS Offline UPS comes with a 1-year warranty.
Under the following conditions, the warranty would not be provided:
• UPS burning due to thunder, abnormal overload, insect entrance and others.
• If ambient temperature should not be maintained at 20 to 26 degrees Celsius with proper dehumidification. (24/7)
• If the product is placed in a dusty and damp place.
• In the absence of Generator connectivity Without proper battery charge, the warranty will be void.
• Battery swelling and overcharging due to the wrong system voltage setting of the UPS.